Comparative study of histological differences according to monopolar radiofrequency tip width

  • Suh, Dong Hye
  • Lee, Sang Doo
  • Kim, Hyun Joo
  • Song, Kye-Yong
  • Shin, Min Kyung
  • 외 2명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Monopolar radiofrequency (RF) devices have improved since 2002, with a significant change in the widths of the tip that comes into direct contact with the skin. We compared the histometric changes between different tip irradiation areas. A total of 28 participants were divided into two groups (14 participants per group) and received a single session of monopolar RF on the face using a 3 & times; 3 cm(2) tip (Group S) or 4 & times; 4 cm(2) tip (Group L). Skin biopsies were performed before and 2 months after treatment. The densities of collagen and elastic fibers in the papillary, upper reticular, and lower reticular dermis were assessed using the ImageJ software. Group L had a higher collagen density in all dermal layers before and after treatment than Group S; this was particularly noted among those aged 20-39 years. Among those aged > 60 years, Group S had higher collagen density in the papillary dermis than Group L. A large-width tip resulted in deeper and more powerful skin tightening, and a small-width tip may be more suitable for older adults.

키워드

Monopolar radiofrequencySkin tighteningCollagen fiberElastic fiber
제목
Comparative study of histological differences according to monopolar radiofrequency tip width
저자
Suh, Dong HyeLee, Sang DooKim, Hyun JooSong, Kye-YongShin, Min KyungLee, Sang JunAhn, Hye-Jin
DOI
10.1007/s10103-026-04951-z
발행일
2026-07
유형
Article
저널명
Lasers in Medical Science
41
1