환형채널 내 저압 미포화비등 유동장의 국소 이상유동 변수 측정

Measurement of Local Two-Phase Flow Parameters in an Annulus Under Low-Pressure Subcooled Boiling Condition
  • 이연건
  • 유지웅
  • 김신
Citations

WEB OF SCIENCE

5
Citations

SCOPUS

5

초록

In this study, an experimental investigation is performed to measure the local bubble parameters in steam-water subcooled boiling flow under atmospheric pressure conditions. The test section is a vertical concentric annulus with an effective height of 2 m, and optical fiber probes are used to measure various local bubble parameters during boiling of the subcooled flow. The local void fraction, mean bubble velocity, interfacial area density, and Sauter mean diameter are measured at four elevations, and their radial profiles are obtained by traversing the tip of optical probes. In the experiments, the flow conditions were set for a heat flux of 370 kW/m2, a mass flux of 430~680 kg/m2s, and an inlet subcooling of 12~18 K at pressures ranging from 114 to 152 kPa.

키워드

Subcooled Flow BoilingOptical Fiber ProbeVertical AnnulusLocal Bubble ParametersBUBBLE PARAMETERS
제목
환형채널 내 저압 미포화비등 유동장의 국소 이상유동 변수 측정
제목 (타언어)
Measurement of Local Two-Phase Flow Parameters in an Annulus Under Low-Pressure Subcooled Boiling Condition
저자
이연건유지웅김신
DOI
10.3795/KSME-B.2018.42.12.813
발행일
2018-12
저널명
대한기계학회논문집 B
42
12
페이지
813 ~ 824