Comparable Graft Failure Rates and Outcome in Superior Capsular Reconstruction Yet Faster Pain Relief Using Dermal Allograft and Faster Motion Recovery Using Tensor Fascia Lata Autograft

Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

OBJECTIVE: This study aims to directly compare clinical outcomes of superior capsular reconstruction (SCR) using dermal allografts (DA) and tensor fascia latae (TFL) autografts, and determine independent factors associated with patient satisfaction and graft failure. METHODS: This retrospective study was conducted between June 2013 and November 2021. Patients who underwent SCR using DA or TFL were included. Inclusion criteria included irreparable rotator cuff tears, a minimum follow-up of 12 months, and age greater than 50 years. Clinical outcomes were evaluated preoperatively and at 6 months, 1 year, and final follow-up. Logistic regression analysis was performed to identify independent factors associated with graft failure and patient satisfaction. Trend analysis was conducted to evaluate changes in outcomes over time. RESULTS: Of initially eligible patients, 16.7% (8/48) from the DA group and 17.1% (7/41) from the TFL group were excluded due to loss to follow-up, resulting in a total of 74 patients analyzed. The average follow-up duration was 34.6 months (range, 23.8-66.0 months) in the DA group and 33.8 months (range, 12.0-60.0 months) in the TFL. The overall graft failure rate was 35.0% in the DA group and 32.4% in the TFL group (p = 0.810). Logistic regression revealed older age, use of DA, and reduced postoperative acromio-humeral distance as significant predictors of graft failure. Graft failure, specifically at the greater tuberosity site, was strongly associated with lower patient satisfaction (OR 0.007, 95% CI 0.000-0.124, p = 0.001). The TFL group showed faster recovery of range of motion (ROM), while the DA experienced more rapid pain relief. CONCLUSIONS: This study showed that graft failure at the greater tuberosity significantly influenced patient dissatisfaction following SCR. Both graft types (DA and TFL) showed similar graft failure rates and clinical outcomes. However, the DA group experienced faster pain relief, whereas the TFL demonstrated earlier recovery of shoulder ROM. METHODS: Retrospective comparative case series; Level III. Copyright © 2025. Published by Elsevier Inc.

키워드

Human Dermal AllograftSuperior Capsule ReconstructionTensor Fascia Lata Autograftfunctional and pain recoverygraft failuregraft failure at greater tuberosityROTATOR CUFF TEARSFUNCTIONAL OUTCOMESSHOULDER ABDUCTIONFATTY DEGENERATIONCLINICAL-OUTCOMESFULL-THICKNESSAGREEMENTMUSCLESPATTERN
제목
Comparable Graft Failure Rates and Outcome in Superior Capsular Reconstruction Yet Faster Pain Relief Using Dermal Allograft and Faster Motion Recovery Using Tensor Fascia Lata Autograft
저자
Alzahrani, Wael MohammedKim, HyojuneJeon, In-HoKoh, Kyoung Hwan
DOI
10.1016/j.arthro.2025.06.008
발행일
2025-11
유형
Article
저널명
Arthroscopy - Journal of Arthroscopic and Related Surgery
41
11
페이지
4493 ~ 4504