Performance standard-based validation study for local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method

  • Ahn, Ilyoung
  • Kim, Tae-Sung
  • Jung, Eun-Sun
  • Yi, Jung-Sun
  • Jang, Won-Hee
  • ... Chun, Young Jin
  • 외 17명
Citations

WEB OF SCIENCE

11
Citations

SCOPUS

15

초록

Local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method (LLNA: BrdU-FCM) is a modified non-radioisotopic technique with the additional advantages of accommodating multiple end-points with the introduction of FCM, and refinement and reduction of animal use by using a sophisticated prescreening scheme. Reliability and accuracy of the LLNA: BrdU-FCM was determined according to OECD Test Guideline (TG) No. 429 (Skin Sensitization: Local Lymph Node Assay) performance standards (PS), with the participation of four laboratories. Transferability was demonstrated through successfully producing stimulation index (SI) values for 25% hexyl cinnamic aldehyde (HCA) consistently greater than 3, a predetermined threshold, by all participating laboratories. Within- and between-laboratory reproducibility was shown using HCA and 2,4-dinitrochlorobenzene, in which EC2.7 values (the estimated concentrations eliciting an SI of 2.7, the threshold for LLNA: BrdU-FCM) fell consistently within the acceptance ranges, 0.025-0.1% and 5-20%, respectively. Predictive capacity was tested using the final protocol version 1.3 for the 18 reference chemicals listed in OECD TG 429, of which results showed 84.6% sensitivity, 100% specificity, and 88.9% accuracy compared with the original LLNA. The data presented are considered to meet the performance criteria for the PS, and its predictive capacity was also sufficiently validated. (C) 2016 Elsevier Inc. All rights reserved.

키워드

Performance standardsValidation studyLocal lymph node assayLLNA: BrdU-FCMSkin sensitizationFlow cytometrySKIN SENSITIZING POTENCYFLOW-CYTOMETRYPREDICTIVE CAPACITYCHEMICALSMOUSE
제목
Performance standard-based validation study for local lymph node assay: 5-bromo-2-deoxyuridine-flow cytometry method
저자
Ahn, IlyoungKim, Tae-SungJung, Eun-SunYi, Jung-SunJang, Won-HeeJung, Kyoung-MiPark, MiyoungJung, Mi-SookJeon, Eun-YoungYeo, Kyeong-ukJo, Ji-HoonPark, Jung-EunKim, Chang-YulPark, Yeong-ChulSeong, Won-KeunLee, Ai YoungChun, Young JinJeong, Tae CheonJeung, Eui BaeLim, Kyung-MinBae, SeungJinSohn, SoojungHeo, Yong
DOI
10.1016/j.yrtph.2016.06.009
발행일
2016-10
유형
Article
저널명
Regulatory Toxicology and Pharmacology
80
페이지
183 ~ 194