Voltammetric determination of trace heavy metals using an electrochemically deposited graphene/bismuth nanocomposite film-modified glassy carbon electrode

Citations

WEB OF SCIENCE

102
Citations

SCOPUS

109

초록

A novel electrochemically deposited graphene (EG)/bismuth (Bi) nanocomposite film-modified glassy carbon electrode (GCE) was prepared through successive electrodeposition of exfoliated graphene oxide (GO) and in situ plating bismuth film. Experimental variables, including deposition potential and bismuth concentration, were carefully optimized to determine trace zinc, cadmium, and lead ions by using the EG/Bi electrode as an electrochemical-sensing platform. The linear calibration curves ranged from 1 to 100 μg L− 1 for Zn2 +, Cd2 +, and Pb2 +. The detection limits were 1.80 μg L− 1 for Zn2 +, 0.18 μg L− 1 for Cd2 +, and 0.11 μg L− 1 for Pb2 + (S/N = 3). The EG/Bi nanocomposite film electrode was successfully applied to the analysis of trace metals in real environments.

키워드

Electrochemically deposited graphene; Bismuth; Heavy metals; Stripping voltammetry; Modified electrode; ANODIC-STRIPPING VOLTAMMETRY; COMPOSITE FILM; OXIDE-FILMS; LARGE-AREA; IN-SITU; LEAD; CADMIUM(II); NANOSHEETS; REDUCTION; GRAPHITE
제목
Voltammetric determination of trace heavy metals using an electrochemically deposited graphene/bismuth nanocomposite film-modified glassy carbon electrode
저자
Lee, Sohee; Park, Seung-Keun; Choi, Eunjin; Piao, Yuanzhe
DOI
10.1016/j.jelechem.2016.02.003
발행일
2016-04
유형
Article
저널명
Journal of Electroanalytical Chemistry
권
766
페이지
120 ~ 127