Structural performance of continuity connection for decked bulb tee girders

Citations

SCOPUS

0

초록

In order to minimize on-site construction, a decked bulb tee (DBT) girder with full-depth concrete deck was proposed. As usage of the precast girder has been increased, interest of connection between girders has been grown in these days. Connection detail has become a critical issue to control girder performance in terms of crack control, strength and rotation capacity of connection part. The purpose of this paper is to suggest recommendation of suitable continuity connection detail for the DBT girders and to verify structural performance of transverse connection detail. Experiment of a small scale-model of DBT girder was performed and recommended connection detail in this paper was based on experimental verification which focused on efficiency of strength, ductility and rotational capacity.

키워드

Accelerated construction; Continuous structure; Decked bulb tee girder; DBT; Precast concrete; Transverse joint; Precast concrete; Structural design; Accelerated constructions; Bulb-tee girders; Continuous structures; Experimental verification; On-site construction; Rotational capacity; Structural performance; Transverse joints; Beams and girders
제목
Structural performance of continuity connection for decked bulb tee girders
저자
Ji, S.W.; Shim, C.S.; Kim, D.W.; Bae, H.U.
발행일
2013
유형
Conference Paper
저널명
Proceedings of the 13th East Asia-Pacific Conference on Structural Engineering and Construction, EASEC 2013