Flexural Behavior of Concrete Beams Internally Prestressed with Unbonded Carbon-Fiber-Reinforced Polymer Tendons

  • Heo, S.
  • Shin, S.
  • Lee, C.
Citations

WEB OF SCIENCE

33
Citations

SCOPUS

34

초록

The objective of this research was to experimentally investigate the effects of the prestressing reinforcement ratio, the magnitude of the prestressing force, the loading type, and the sectional shape on the flexural behavior of beams internally prestressed with unbonded carbon-fiber-reinforced polymer (CFRP) tendons. Four rectangular and three T-beams were tested. Test results have shown that, even for the unbonded prestressing ratio less than the balanced ratio of the bonded equivalent, unbonding the CFRP tendons could relieve tendon strains along the beam span and delay the rupture of CFRP tendons. Improved ductility was observed for the rectangular beams prestressed with unbonded CFRP tendons and non-prestressed auxiliary bonded steel bars when compared with prestressed beams that have bonded CFRP tendons. DOI: 10.1061/(ASCE)CC.1943-5614.0000306. (C) 2013 American Society of Civil Engineers.

키워드

Carbon-fiber-reinforced polymer (CFRP)Fiber-reinforced polymerFlexural strengthTestsUnbonded prestressed concretePOSTTENSIONING TENDONSFRP TENDONSULTIMATESTRESS
제목
Flexural Behavior of Concrete Beams Internally Prestressed with Unbonded Carbon-Fiber-Reinforced Polymer Tendons
저자
Heo, S.Shin, S.Lee, C.
DOI
10.1061/(ASCE)CC.1943-5614.0000306
발행일
2013-03
유형
Article
저널명
Journal of Composites for Construction
17
2
페이지
167 ~ 175