Repeatability of amide proton transfer-weighted signals in the brain according to clinical condition and anatomical location

  • Lee, Jung Bin; 
  • Park, Ji Eun; 
  • Jung, Seung Chai; 
  • Jo, Youngheun; 
  • Kim, Donghyun; 
  • 외 4명
Citations

WEB OF SCIENCE

24
Citations

SCOPUS

25

초록

Objectives To investigate whether clinical condition, imaging session, and locations affect repeatability of amide proton transfer-weighted (APTw) magnetic resonance imaging (MRI) in the brain. Materials and methods Three APTw MRI data sets were acquired, involving two intrasession scans and one intersession scan for 19 healthy, 15 glioma, and 12 acute stroke adult participants (mean age 53.8, 54.6, and 68.5, respectively) on a 3T MR scanner. The mean APTw signals from five locations in healthy brain (supratentorial and infratentorial locations) and from entire tumor and stroke lesions (supratentorial location) were calculated. The within-subject coefficient of variation (wCV) and intraclass correlation coefficient (ICC) were calculated for each clinical conditions, image sessions, and anatomic locations. Differences in APTw signals between sessions were analyzed using repeated-measures analysis of variance. Results The ICC and wCV were 0.96 (95% confidence interval [CI], 0.91-0.99) and 16.1 (12.6-21.3) in glioma, 0.93 (0.82-0.98) and 15.0 (11.4-20.6) in stroke, and 0.84 (0.72-0.91) and 34.0 (28.7-41.0) in healthy brain. There were no significant differences in APTw signal between three sessions, irrespective of disease condition and location. The ICC and wCV were 0.85 (0.68-0.94) and 27.4 (21.8-35.6) in supratentorial, and 0.44 (- 0.18 to 0.76) and 32.7 (25.9 to 42.9) in infratentorial locations. There were significant differences in APTw signal between supra- (mean, 0.49%; 95% CI, 0.38-0.61) and infratentorial locations (1.09%, 0.98-1.20; p < 0.001). Conclusion The repeatability of APTw signal was excellent in supratentorial locations, while it was poor in infratentorial locations due to severe B0 inhomogeneity and susceptibility which affects MTR asymmetry.

키워드

Amides; Repeatability; Brain tumors; Stroke; Magnetic resonance imaging; EXCHANGE SATURATION-TRANSFER; HIGH-GRADE GLIOMAS; CHEMICAL-EXCHANGE; PH; ACQUISITION; CLASSIFICATION; BIOMARKERS; PROTEINS; CONTRAST; AGENTS
제목
Repeatability of amide proton transfer-weighted signals in the brain according to clinical condition and anatomical location
저자
Lee, Jung Bin; Park, Ji Eun; Jung, Seung Chai; Jo, Youngheun; Kim, Donghyun; Kim, Ho Sung; Choi, Choong-Gon; Kim, Sang Joon; Kang, Dong-Wha
DOI
10.1007/s00330-019-06285-7
발행일
2020-01
유형
Article
저널명
European Radiology
권
30
호
1
페이지
346 ~ 356