Fine Needle Aspiration of Parotid Tumors: Diagnostic Utility From a Clinical Perspective

  • Jeong, Woo-Jin; 
  • Park, Sung Joon; 
  • Cha, Wonjae; 
  • Sung, Myung-Whun; 
  • Kim, Kwang Hyun; 
  • 외 1명
Citations

WEB OF SCIENCE

18
Citations

SCOPUS

17

초록

Purpose: The utility of fine needle aspiration (FNA) for parotid tumors is limited owing to its low diagnostic accuracy. In this study, the authors sought to analyze and interpret FNA results for parotid tumors from a clinical perspective. Materials and Methods: Parotid tumors subjected to preoperative FNA and subsequent complete excision were the subject of this study. Patient demographics, medical records, FNA findings, and final pathology of 158 consecutive cases were analyzed. Results: The accuracy of FNA was 77.8%. The positive predictive value and likelihood ratio for malignancy were 90.0% and 52.8% (95% confidence interval, 7.02-397), respectively. The positive predictive value and likelihood ratio for benign pathology of Warthin tumor plus pleomorphic adenoma were 97.8% and 7.67% (2.03-29.0), respectively. Conclusions: The FNA diagnosis of Warthin tumor or pleomorphic adenoma is reliable and can be safely regarded as a benign tumor. Based on the high positive predictive value and likelihood ratio, FNA of the parotid gland can offer valuable information in surgical planning and patient counseling in many centers. (C) 2013 American Association of Oral and Maxillofacial Surgeons

키워드

SALIVARY-GLAND LESIONS; CYTOLOGY; ACCURACY; BIOPSY
제목
Fine Needle Aspiration of Parotid Tumors: Diagnostic Utility From a Clinical Perspective
저자
Jeong, Woo-Jin; Park, Sung Joon; Cha, Wonjae; Sung, Myung-Whun; Kim, Kwang Hyun; Ahn, Soon-Hyun
DOI
10.1016/j.joms.2013.01.017
발행일
2013-07
유형
Article
저널명
Journal of Oral and Maxillofacial Surgery
권
71
호
7
페이지
1278 ~ 1282