인 처리시설 시운전 및 정상운전 자료 비교·분석 연구

A Comparative Study on Start-up and Normal Operation Data for Phosphorus Removal in WWTPs
  • 윤소영; 
  • 유재나; 
  • 김종욱; 
  • 오재일

초록

This study aimed to obtain quantitative data for WWTP operators in phosphorus removal process. This was done by reviewing and comparing phosphorus removal efficiency(%), coagulants dosage(Al/P and Al2O3(mg/L)), sludge production(kg/㎥), and operation cost(won/㎥) of start-up and normal operation data. Phosphorus removal efficiency of all tertiary treatment process was up to 70 ~ 89 % in start-up and normal operation. Average molar ratio(Al/P) was similar as 5 in both operations, but average coagulants dosage (mg/L) of start-up (8.5 mg/L) was higher than normal operation (6.2 mg/L). Average operation cost was higher for start-up (33.6 won/㎥) than normal operation (28.4 won/㎥), while electricity cost was required for the normal operation (9.0 won/㎥) was higher by 3.5 won/㎥.

키워드

A Comparative Study on Start-up and Normal Operation Data for Phosphorus Removal in WWTPs; 인 처리시설 시운전 및 정상운전 자료 비교·분석 연구
제목
인 처리시설 시운전 및 정상운전 자료 비교·분석 연구
제목 (타언어)
A Comparative Study on Start-up and Normal Operation Data for Phosphorus Removal in WWTPs
저자
윤소영; 유재나; 김종욱; 오재일
DOI
10.11001/jksww.2013.27.1.113
발행일
2013-02
저널명
상하수도학회지
권
27
호
1
페이지
113 ~ 120