CFD Simulation of Microchannel Reactor Block for Fischer-Tropsch Synthesis: Effect of Coolant Type and Wall Boiling Condition on Reactor Temperature

  • Kshetrimayum, Krishnadash S.; 
  • Jung, Ikhwan; 
  • Na, Jonggeol; 
  • Park, Seongho; 
  • Lee, Yongkyu; 
  • ... Lee, Chul-Jin; 
  • 외 2명
Citations

WEB OF SCIENCE

25
Citations

SCOPUS

26

초록

Computational fluid dynamic (CFD) simulation of heat transfer in a microchannel reactor block for low temperature Fischer-Tropsch (FT) synthesis was considered. Heat generation profiles for different operating conditions (GHSV 5000 h(-1); catalyst loading 60%-120%, where 100% loading equals 1060 kg/m(3) of cobalt based catalyst from Oxford Catalyst Ltd.) were obtained from a single channel model. Simulations on a reactor block quantified the effects of three coolant types: cooling oil (Merlotherm SH), subcooled water and saturated water, on reactor temperature, and also evaluated the effect of wall boiling conditions. At process conditions of GHSV 5000 h(-1) and catalyst loading of 120%, predicted temperature gradients along channel length were 32, 17 and 12 K for cooling oil, subcooled water and saturated water, respectively. A modified reactor block showed improved thermal performance as well as heat transfer enhancement due to wall boiling conditions.

키워드

FIXED-BED REACTOR; KINETICS; PERFORMANCE; SELECTIVITY; DESIGN; MODEL
제목
CFD Simulation of Microchannel Reactor Block for Fischer-Tropsch Synthesis: Effect of Coolant Type and Wall Boiling Condition on Reactor Temperature
저자
Kshetrimayum, Krishnadash S.; Jung, Ikhwan; Na, Jonggeol; Park, Seongho; Lee, Yongkyu; Park, Seongeon; Lee, Chul-Jin; Han, Chonghun
DOI
10.1021/acs.iecr.5b03283
발행일
2016-01
유형
Article
저널명
Industrial & Engineering Chemistry Research
권
55
호
3
페이지
543 ~ 554