Comparison of the Diagnostic Performance of Synthetic Versus Acquired High b-Value (1500 s/mm(2)) Diffusion-Weighted MRI in Women With Breast Cancers

  • Park, Jung Hyun; 
  • Yun, Bo La; 
  • Jang, Mijung; 
  • Ahn, Hye Shin; 
  • Kim, Sun Mi; 
  • 외 4명
Citations

WEB OF SCIENCE

23
Citations

SCOPUS

26

초록

BackgroundAcquired high b-value (>1000 s/mm(2)) diffusion-weighted imaging (DWI) has its strength in lesion detection. However, it is not easily used, due to a lower signal-to-noise ratio, eddy current distortions, and prolonged acquisition times. Synthetic DWI does not have these disadvantages because it is based on indirect acquisition, calculated in a voxel-wise manner. PurposeTo compare the diagnostic performance of synthetic and acquired high b-value (1500 s/mm(2)) DWI in women with breast cancer. Study TypeRetrospective. PopulationA total of 108 patients (median age 49 years [range 32-77]) with 133 breast cancers. Field Strength/Sequence3T, echo-planar imaging. AssessmentThree radiologists independently reviewed image sets of both synthetic (S-b1500) and acquired (A-b1500) high b-value DWI. Malignancy confidence of the lesion was scored using a 6-point Likert-type scale. Statistical TestJack-knife alternative free-response receiver-operating characteristic 1 (JAFROC1) analysis was used. Sensitivity and positive predictive value (PPV) were compared using generalized estimating equations. An independent t-test was used to compare the confidence. An intraclass correlation coefficient was calculated to compare interobserver agreement. ResultsThe JAFROC1 figures of merit values were 0.816 and 0.808 in S-b1500 and A-b1500, respectively, with no statistically significant difference (P=0.637). Sensitivity was higher in synthetic than in A-b1500 for readers 2 (P=0.015) and 3 (P=0.037). Although sensitivity was higher in S-b1500 than in A-b1500 for reader 1, the difference was not significant (P=0.487). The PPV of S-b1500 was not significantly different from that of A-b1500 (P=0.397). The malignancy confidence of true-positive tumors was higher in S-b1500 than in A-b1500 (P=0.013). Interobserver agreement was good for both sequences. Data ConclusionsThe synthetic high b-value DWI may improve the diagnostic sensitivity for breast cancer detection without affecting PPV compared with acquired high b-value DWI. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:857-863.

키워드

breast neoplasms; magnetic resonance imaging; diffusion magnetic resonance imaging; image interpretation; computer-assisted; predictive value of tests; PROSPECTIVE MULTICENTER COHORT; FAMILIAL RISK; MAMMOGRAPHY; ULTRASOUND; POPULATION; RECOMMENDATIONS; TOMOSYNTHESIS; FEASIBILITY; PROTOCOL; IMAGES
제목
Comparison of the Diagnostic Performance of Synthetic Versus Acquired High b-Value (1500 s/mm(2)) Diffusion-Weighted MRI in Women With Breast Cancers
저자
Park, Jung Hyun; Yun, Bo La; Jang, Mijung; Ahn, Hye Shin; Kim, Sun Mi; Lee, Soo Hyun; Kang, Eunyoung; Kim, Eun-Kyu; Park, So Yeon
DOI
10.1002/jmri.26259
발행일
2019-03
유형
Article
저널명
Journal of Magnetic Resonance Imaging
권
49
호
3
페이지
857 ~ 863