삼차원집적공정에서 원자현미경을 활용한 Wafer Bonding Strength 측정 방법의 신뢰성에 관한 연구

Reliable Measurement Methodology of Wafer Bonding Strength in 3D Integration Process Using Atomic Force Microscopy

초록

The wafer bonding process becomes a flexible approach to material and device integration. The bonding strength in 3-dimensional process is crucial factor in various interface bonding process such as silicon to silicon, silicon to metals such as oxides to adhesive intermediates. A measurement method of bonding strength was proposed by utilizing AFM applied CNT probe tip which indicated the relative simplicity in preparation of sample and to have merit capable to measure regardless type of films. Also, New Tool was utilized to measure of tip radius. The cleaned SiO2-Si bonding strength of SPFM indicated 0.089 J/m2, and the cleaning result by RCA 1(NH4OH:H2O:H2O2) measured 0.044 J/m2,indicated negligible tolerance which verified the possibility capable to measure accurate bonding strength. And it could be confirmed the effective bonding is possible through SPFM cleaning.

키워드

Atomic Force Microscopy; Bonding Strength; Cleaning; Wafer Bonding; SPFM
제목
삼차원집적공정에서 원자현미경을 활용한 Wafer Bonding Strength 측정 방법의 신뢰성에 관한 연구
제목 (타언어)
Reliable Measurement Methodology of Wafer Bonding Strength in 3D Integration Process Using Atomic Force Microscopy
저자
최은미; 표성규
DOI
10.6117/kmeps.2013.20.2.011
발행일
2013-06
저널명
마이크로전자 및 패키징학회지
권
20
호
2
페이지