굴곡성 후두내시경의 Cidex Ortho-Phthalaldehyde 침적 시간에 따른 소독 효과 평가: 다기관 연구
Evaluation of Disinfection Efficacy in Flexible Laryngoscopy According to Cidex Ortho-Phthalaldehyde Immersion Time: A Multicenter Study
  • 이영찬
  • 박혜상
  • 김희진
  • 최나연
  • 이상혁
  • ... 이세영
  • 외 1명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Background and Objectives Flexible laryngoscopes are indispensable tools in otolaryngology, but their frequent use makes them vulnerable to contamination, thus posing a risk of cross-infection. Unlike gastrointestinal endoscopes, flexible laryngoscopes currently lack standardized disinfection protocols. This study evaluates the efficacy of Cidex OPA (0.55% ortho-phthalaldehyde) to establish an effective, practical disinfection protocol for flexible laryngoscopes.Materials and Method This multicenter study involved the use of flexible laryngoscopes in otolaryngology outpatient clinics across five university hospitals. Laryngoscopes were immersed in Cidex OPA for 1, 5, or 12 minutes, with an additional group treated using Tristel wipes and foam after a 12-minute immersion. Swab samples were collected from the distal 15 cm of each laryngoscope following disinfection and cultured on blood agar plates under aerobic conditions at 35°C–37°C with 5% CO<sub>2</sub> for 72 hours. Positive controls included laryngoscopes directly contaminated with saliva or laryngeal secretions.Results Six out of ten positive control samples demonstrated bacterial growth. However, no bacterial growth was observed in any sample from the Cidex OPA immersion groups (1, 5, or 12 minutes), including the group treated with Tristel. These findings indicate that even a 1-minute immersion in Cidex OPA effectively eliminates bacterial contamination.Conclusion This study provides evidence supporting an efficient disinfection method that can enhance infection control and streamline clinical workflow. Further research with a larger sample size and varied disinfection techniques is needed to establish comprehensive disinfection guidelines for flexible laryngoscopes.

키워드

LaryngoscopesDisinfectionCross infection preventionOrtho-phthalaldehydeHigh-level disinfection후두경소독교차감염 예방오르토프탈알데히드높은 수준 소독
제목
굴곡성 후두내시경의 Cidex Ortho-Phthalaldehyde 침적 시간에 따른 소독 효과 평가: 다기관 연구
제목 (타언어)
Evaluation of Disinfection Efficacy in Flexible Laryngoscopy According to Cidex Ortho-Phthalaldehyde Immersion Time: A Multicenter Study
저자
이영찬박혜상김희진최나연이상혁이세영조광재
DOI
10.22469/jkslp.2024.35.3.89
발행일
2024-12
저널명
대한후두음성언어의학회지
35
3
페이지
89 ~ 93

파일 다운로드