Placing a Saline Bag Underneath the Heart Enhances Transgastric Transesophageal Echocardiographic Imaging During Cardiac Displacement for Off-Pump Coronary Artery Bypass Surgery

  • Sung, Tae-Yun
  • Kwon, Mi-Young
  • Bin Muhammad, Hasimizy
  • Kim, Ju-Duck
  • Kang, Woon-Seok
  • ... Kang, Hyun
  • 외 5명
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

5

초록

Objective: The authors hypothesized that placing a saline bag (saline-filled surgical glove) underneath a displaced heart would improve ultrasound transmission for transgastric (TG) imaging and transesophageal echocardiography (TEE) to visualize left ventricular regional wall motion (LV-RWM) during cardiac displacement for off-pump coronary artery bypass (OPCAB) surgery. Design: Prospective observational study. Setting: Tertiary University Hospital. Participants: Adult patients undergoing OPCAB surgery. Interventions: Intraoperative TEE examination Measurement and Main Results: For off-line analyses of LV-readable segments, mid-esophageal (ME, 4-chamber, 2-chamber, and long-axis) and TG (basal- and mid-short-axis) TEE views were recorded under 3 different intraoperative conditions in 13 cases of OPCAB surgery: Before cardiac displacement (T-control), after cardiac displacement (T-displaced), and after placing the saline bag underneath the displaced heart (Tsaline-bag). There were more LV-readable segments in the 17-segment model using integrated ME and TG views (ME + TG views) at Tsaline-bag and T-control (mean[95% confidence interval], 17[17-17] and 17[17-17]) than using ME+TG at T-displaced (15[15-16], P = 0.002 and P<0.001, respectively). Using ME + TG views provided more LV-readable segments in the 17-segment model than using ME views at Tsaline-bag (vs. 16[14-16], P < 0.001), but not at T-displaced (vs. 15[14-15]). Incidences of inadequate RWM monitoring (LV-readable segments<14/17 using ME + TG views) at Tsaline-bag and T-control (all 0/13) were less frequent than at T-displaced (3/13, all P = 0.038). There were more LV-readable segments in TG basal-and mid-short-axis views at Tsaline-bag (median [range], 6[5-6] and 5[5-6]) than at T-displaced (0[0-2] and 0[0-1], all P < 0.05). Conclusions: Placing a saline bag underneath the displaced heart enhances the ability of TEE to visualize global LV-RWM by improving TG TEE imaging during OPCAB surgery. (c) 2014 Elsevier Inc. All rights reserved.

키워드

off-pump coronary artery bypass surgerysaline bagtransesophageal echocardiographycardiac surgerycardiac displacementstabilizersWALL-MOTION ABNORMALITIESHEMODYNAMIC-CHANGESAMERICAN-SOCIETYBEATING HEARTASSOCIATIONRECOMMENDATIONSGUIDELINESCARDIOLOGYCOMMITTEEISCHEMIA
제목
Placing a Saline Bag Underneath the Heart Enhances Transgastric Transesophageal Echocardiographic Imaging During Cardiac Displacement for Off-Pump Coronary Artery Bypass Surgery
저자
Sung, Tae-YunKwon, Mi-YoungBin Muhammad, HasimizyKim, Ju-DuckKang, Woon-SeokKim, Seong-HyopKim, Duk-KyoungYoon, Tae-GyoonKim, Tae-YopKim, Ji-HyunKang, Hyun
DOI
10.1053/j.jvca.2013.04.011
발행일
2014-02
유형
Article
저널명
Journal of Cardiothoracic and Vascular Anesthesia
28
1
페이지
42 ~ 48