Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis

  • Oh, Hyoung-Chul; 
  • Kang, Hyun; 
  • Lee, Jae Young; 
  • Choi, Geun Joo; 
  • Choi, Jung Sik
Citations

WEB OF SCIENCE

25
Citations

SCOPUS

21

초록

Background/Aims: To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Methods: Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. Results: The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Conclusions: Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

키워드

Endoscopic ultrasound; Fine needle aspiration; Core needle; SOLID PANCREATIC LESIONS; BIOPSY NEEDLE; 22-GAUGE NEEDLE; FNA BIOPSY; EUS-FNA; ASPIRATION; MASSES; FEASIBILITY; MULTICENTER; YIELD
제목
Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis
저자
Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik
DOI
10.3904/kjim.2016.066
발행일
2016-11
유형
Article
저널명
The Korean Journal of Internal Medicine
권
31
호
6
페이지
1073 ~ 1083

파일 다운로드

Thumbnail