상세 보기
A modified approach for measuring the air permeability of ultra-high performance concrete (UHPC) under vacuum conditions
- Dahal, Mandip;
- Park, Sungwoo;
- Pyo, Sukhoon
WEB OF SCIENCE
15SCOPUS
16초록
This study proposes a novel test method of the air permeability measurement under extreme vacuum condition to examine the performance of materials for Hyperloop tubes. Tests on cement-based materials demonstrated that the developed test setup was effective in measuring air permeability in extreme vacuum conditions. The results show that ultra-high performance concrete (UHPC) has significantly lower air permeability (10–18 m2) in vacuum conditions than other cement-based materials (10–16 m2) due to its dense microstructure and reduced pore size, which were within the range of previous results (10-18-10-16 m2). The measured porosity results had a strong correlation with air permeability (R2 > 0.97), validating the suitability of the proposed method for measuring the air permeability of cement-based materials in vacuum conditions. These findings provide fundamental material properties for the design of Hyperloop tube structures.
키워드
- 제목
- A modified approach for measuring the air permeability of ultra-high performance concrete (UHPC) under vacuum conditions
- 저자
- Dahal, Mandip; Park, Sungwoo; Pyo, Sukhoon
- 발행일
- 2023-10
- 유형
- Article
- 권
- 401
- 언어
- ENG
- 출판사
- Elsevier Ltd
- 발행국가
- 영국
- ISSN
- E 1879-0526
P 0950-0618