HPLC and UPLC methods for the determination of zearalenone in noodles, cereal snacks and infant formula

Citations

WEB OF SCIENCE

80
Citations

SCOPUS

89

초록

High-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were compared to validate a method for determination of zearalenone (ZON) in noodles, cereal snacks, and infant formulas. The limits of detection and quantification in HPLC and UPLC were found to be 4.0 and 13.0 mu g kg(-1) and 2.5 and 8.3 mu g kg(-1), respectively. The average recoveries of ZON by HPLC and UPLC ranged from 79.1% to 105.3% and from 85.1% to 114.5%, respectively. The measurement uncertainties of the two methods for ZON determination were within the maximum standard uncertainty. The two methods showed that the levels of ZON in 163 naturally contaminated samples ranged from 4.3 to 8.3 mu g kg(-)1 by HPLC and 3.1 to 17.6 mu g kg(-1) by UPLC. These findings indicate that either method is suitable for the determination of ZON in noodles, cereal snacks, and infant formulas, but UPLC gives faster results with better sensitivity. (C) 2014 Elsevier Ltd. All rights reserved.

키워드

Zearalenone; HPLC; UPLC; Noodles; Cereal snacks; Infant formulas; PERFORMANCE LIQUID-CHROMATOGRAPHY; WHEAT
제목
HPLC and UPLC methods for the determination of zearalenone in noodles, cereal snacks and infant formula
저자
Ok, Hyun Ee; Choi, Sung-Wook; Kim, Meehye; Chun, Hyang Sook
DOI
10.1016/j.foodchem.2014.04.111
발행일
2014-11
유형
Article
저널명
Food Chemistry
권
163
페이지
252 ~ 257