A retrospective multicentre study on the evaluation of perioperative outcomes of single-port robotic cholecystectomy comparing the Xi and SP versions of the da Vinci robotic surgical system

  • Kang, Yoon Hyung; 
  • Kang, Jae Seung; 
  • Cho, Yo Seok; 
  • Kim, Hyeong Seok; 
  • Lee, Mirang; 
  • ... Sohn, Hee Ju; 
  • 외 5명
Citations

WEB OF SCIENCE

12
Citations

SCOPUS

14

초록

Background Single-incision robotic cholecystectomy (SIRC) is widely performed with both the da Vinci Xi system (Xi) and the da Vinci SP system (SP). But there are limited numbers of studies comparing these platforms. Methods Patients who underwent SIRC between 2019 and 2020 were enrolled. Patient demographics, intraoperative factors, postoperative complications, postoperative pain were compared using a one-to-one propensity score matching (PSM). Results Overall, 258 patients underwent SIRC with Xi and 72 with SP. After PSM, there were significant differences between the Xi and SP in operation time at console and numeric rating scale for postoperative pain, but no difference in total operation time and postoperative complications. The SP group showed more estimated blood loss. Conclusions Despite the statistical difference, clinical benefit was not significant. Both platforms can be safe and feasible to perform SIRC, but further investigation including the surgeon's workload and ergonomics is needed as a prospective study.

키워드

cholecystectomy; Da Vinci SP; Da Vinci Xi; robotic surgery; INCISION LAPAROSCOPIC CHOLECYSTECTOMY; SURGERY; EXPERIENCE
제목
A retrospective multicentre study on the evaluation of perioperative outcomes of single-port robotic cholecystectomy comparing the Xi and SP versions of the da Vinci robotic surgical system
저자
Kang, Yoon Hyung; Kang, Jae Seung; Cho, Yo Seok; Kim, Hyeong Seok; Lee, Mirang; Han, Youngmin; Sohn, Hee Ju; Kim, Hongbeom; Kwon, Wooil; Jang, Jin-Young; Lee, Hyeon Kook
DOI
10.1002/rcs.2345
발행일
2022-02
유형
Article
저널명
International Journal of Medical Robotics and Computer Assisted Surgery
권
18
호
1