This paper proposes a method for driving the gate power supply of a pulsed carbon nanotube(CNT) X-ray system using an IP controller. The pulsed CNT X-ray system consists of a tube power supply and a gate power supply, offering advantages such as rapid X-ray emission control, miniaturization, and reduced radiation exposure compared to conventional thermionic Xray systems. To achieve fast response and stable gate voltage supply, an appropriate gate control method is essential. Commonly used proportional-integral(PI) and proportional-integralderivative(PID) controllers have limitations: PI controllers are prone to high overshoot and sensitivity to controller gains, while PID controllers are affected by noise amplification in highfrequency ranges. Furthermore, the slow response of tube current to gate voltage variations in CNT X-ray tubes exacerbates the overshoot issue in PI controllers.