상세 보기
Supplementary Control of Conventional Coordinated Control for 1000 MW Ultra-Supercritical Thermal Power Plant Using One-Step Ahead Control
- Choi, Hyuk;
- Choi, Yeongseok;
- Moon, Un-Chul;
- Lee, Kwang Y.
WEB OF SCIENCE
4SCOPUS
5초록
The intermittence of renewable energy sources increases the importance of the effective load-tracking ability of power plants. Coordinated control between boiler and turbine systems is the uppermost layer of a thermal power plant control to follow the load demand. In this paper, a supplementary controller is proposed based on the One-Step Ahead strategy for coordinated control of thermal power plants. After a plant model is developed offline from a step response test, the optimized control of the One-Step Ahead strategy is applied to the boiler feed-forward (BFF) signal to control the electric power output and the main steam pressure simultaneously. Simulation with a 1000 MW ultra-supercritical (USC) once-through type power plant is performed. The results show that the error of Mega-Watt Output (MWO) was reduced to 78~95%, and settling time was reduced to 64~79% from conventional coordinated control by adding the proposed supplementary controller. © 2023 by the authors.
키워드
- 제목
- Supplementary Control of Conventional Coordinated Control for 1000 MW Ultra-Supercritical Thermal Power Plant Using One-Step Ahead Control
- 저자
- Choi, Hyuk; Choi, Yeongseok; Moon, Un-Chul; Lee, Kwang Y.
- 발행일
- 2023-09
- 유형
- Article
- 저널명
- Energies
- 권
- 16
- 호
- 17