Unlike X-ray systems, a terahertz imaging system can distinguish low-density materials in a food matrix. For applying this technique to food inspection, imaging resolution and acquisition speed ought to be simultaneously enhanced. Therefore, we have developed the first continuous-wave sub-terahertz transmission imaging system with a polygonal mirror. Using an f-theta lens and a polygonal mirror, beam scanning is performed over a range of 150 mm. For obtaining transmission images, the line-beam is incorporated with sample translation. The imaging system demonstrates that a pattern with 2.83 mm line-width at 210 GHz can be identified with a scanning speed of 80 mm/s. (C) 2015 Optical Society of America

키워드

REFLECTION TOMOGRAPHYFOREIGN-BODIES
제목
High-performance sub-terahertz transmission imaging system for food inspection
저자
Ok, GyeongsikPark, KisangChun, Hyang SookChang, Hyun-JooLee, NariChoi, Sung-Wook
DOI
10.1364/BOE.6.001929
발행일
2015-05
유형
Article
저널명
Biomedical Optics Express
6
5
페이지
1929 ~ 1941