상세 보기
Fabrication of all glass microfluidic device with superior chemical and mechanical resistances by glass molding with vitreous carbon mold
- Haq, Muhammad Refatul;
- Kim, Young Kyu;
- Kim, Jun;
- Ju, Jonghyun;
- Kim, Seok-min
WEB OF SCIENCE
23SCOPUS
25초록
A glass microfluidic device with superior chemical and mechanical resistance was fabricated using a cost-effective glass molding process with a vitreous carbon (VC) mold, which was prepared by the carbonization of a replicated polymer precursor. For the development of microfluidic chips with dense microchannels on a large footprint, a defect-free VC mold is essential. In this study, a furan imprinting process, in which a patterned furan layer was imprinted (cured) on a polished furan plate, was established to minimize warpage and gas bubble defects. In addition, the proposed imprinting process markedly reduced the fabrication time of the furan precursor. For feasibility testing, a glass micromixer with a total channel length of 30.6 cm and footprint of 20 x 20 mm(2) was developed by glass molding with the VC mold and thermal fusion bonding. The fabricated glass-molded micromixer was durable at an internal pressure of similar to 24 MPa, and there was no swelling when used with toluene for an extended time.
키워드
- 제목
- Fabrication of all glass microfluidic device with superior chemical and mechanical resistances by glass molding with vitreous carbon mold
- 저자
- Haq, Muhammad Refatul; Kim, Young Kyu; Kim, Jun; Ju, Jonghyun; Kim, Seok-min
- 발행일
- 2019-07
- 유형
- Article
- 권
- 29
- 호
- 7
- 언어
- ENG
- 출판사
- IOP PUBLISHING LTD
- 발행국가
- 영국
- ISSN
- E 1361-6439
P 0960-1317