상세 보기
새로운 응축열전달계수 상관식이 적용된 MARS-KS를 활용한 원자로건물 피동냉각계통 열제거 성능의 수치적 연구
- 장영준;
- 이연건;
- 김신;
- 임상규
초록
The passive containment cooling system (PCCS) has been designed to remove the released decayheat during the accident by means of the condensation heat transfer phenomenon to guarantee the safetyof the nuclear power plant. The heat removal performance of the PCCS is mainly governed by the condensationheat transfer of the steam-air mixture. In this study, the heat removal performance of the PCCSwas evaluated by using the MARS-KS code with a new empirical correlation for steam condensation inthe presence of a noncondensable gas. A new empirical correlation implemented into the MARS-KS codewas developed as a function of parameters that affect the condensation heat transfer coefficient, such asthe pressure, the wall subcooling, the noncondensable gas mass fraction and the aspect ratio of the condensertube. The empirical correlation was applied to the MARS-KS code to replace the default Colburn-Hougenmodel. The various thermal-hydraulic parameters during the operation of the PCCS follonwing a large-breakloss-of-coolant-accident were analyzed. The transient pressure behavior inside the containment from theMARS-KS with the empirical correlation was compared with calculated with the Colburn-Hougen model.
키워드
- 제목
- 새로운 응축열전달계수 상관식이 적용된 MARS-KS를 활용한 원자로건물 피동냉각계통 열제거 성능의 수치적 연구
- 제목 (타언어)
- Numerical Study of the Heat Removal Performance for a Passive Containment Cooling System using MARS-KS with a New Empirical Correlation of Steam Condensation
- 저자
- 장영준; 이연건; 김신; 임상규
- 발행일
- 2018-12
- 저널명
- 에너지공학
- 권
- 27
- 호
- 4
- 페이지
- 27 ~ 35
- 언어
- KOR
- 출판사
- 한국에너지학회
- 발행국가
- 대한민국
- 분량
- 9 페이지
- ISSN
- P 1598-7981