수직 튜브 외벽에서의 증기-비응축성 기체 응축 열전달 실험 연구
- 이연건;
- 장영준;
- 최동재;
- 김신
초록
To evaluate the heat removal capability of a condenser tube in the PCCS of an advanced nuclear power plant, a steam condensation experiment in the presence of noncondensable gas on a vertical tube is performed. The average heat transfer coefficient is measured on a vertical tube of 40 mm in O.D. and 1.0 m in length. The experiments covers the pressures of 2-4 bar, and the mass fraction of air ranges from 0.1 up to 0.7. From the experimental results, the effects of the total pressure and the concentration of air on the condensation heat transfer coefficient are investigated. The measured data are compared with the predictions by Uchida’s and Tagami’s correlations, and it is revealed that these models underestimate the condensation heat transfer coefficient of the steam-air mixture.
키워드
- 제목
- 수직 튜브 외벽에서의 증기-비응축성 기체 응축 열전달 실험 연구
- 제목 (타언어)
- Experimental Investigation of Steam Condensation Heat Transfer in the Presence of Noncondensable Gas on a Vertical Tube
- 저자
- 이연건; 장영준; 최동재; 김신
- 발행일
- 2015-03
- 저널명
- 에너지공학
- 권
- 24
- 호
- 1
- 페이지
- 42 ~ 50
- 출판사
- 한국에너지학회
- 발행국가
- 대한민국
- 분량
- 9 페이지
- ISSN
- P 1598-7981