Phased array calibration system with high accuracy and low complexity

  • Kim, S.
  • Dong, H.-J.
  • Yu, J.-W.
  • Lee, H.L.
Citations

WEB OF SCIENCE

23
Citations

SCOPUS

27

초록

This paper presents a highly efficient phased array calibration system for phase and magnitude error correction. The proposed calibration system is based on far-field scanning of the array antenna under test at factory level. Since the proposed structure requires a magnitude detection only for vector calibration, low circuit complexity can be achieved. Unlike the conventional far-field calibration based on rotating-element electric-field vector (REV) method to find maximum vector-sum point, the proposed system detects the minimum vector-sum point and tracks the behavior of the null point. To verify the feasibility of the proposed system for large-scale array antenna, 4 × 4 phased array antenna is implemented at 5.8 GHz. Then, the proposed method is applied to the phased array antenna and compared with the conventional REV method. © 2023 THE AUTHORS

키워드

Antenna array calibrationBeamforming calibrationPhased arrayVector calibration systemANTENNACOMPENSATIONCHALLENGES
제목
Phased array calibration system with high accuracy and low complexity
저자
Kim, S.Dong, H.-J.Yu, J.-W.Lee, H.L.
DOI
10.1016/j.aej.2023.02.026
발행일
2023-04
유형
Article
저널명
AEJ - Alexandria Engineering Journal
69
페이지
759 ~ 770

파일 다운로드