Reliability and validity of isometric knee extensor strength test with hand-held dynamometer depending on its fixation: A pilot study

Citations

SCOPUS

87

초록

Objective: To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer. Methods: Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35° angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results: The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion: Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength. © 2014 by Korean Academy of Rehabilitation Medicine.

키워드

Dimensional measurement accuracy; Isometric contraction; Knee joint; Muscle strength dynamometer; Physical restraint
제목
Reliability and validity of isometric knee extensor strength test with hand-held dynamometer depending on its fixation: A pilot study
저자
Kim, W.K.; Kim, D.-K.; Seo, K.M.; Kang, S.H.
DOI
10.5535/arm.2014.38.1.84
발행일
2014-02
유형
Article
저널명
Annals of Rehabilitation Medicine
권
38
호
1
페이지
84 ~ 93

파일 다운로드

Thumbnail