상세 보기
Determination of a novel low-voltage-activated calcium channel blocker (HYP-10) in rat plasma by liquid chromatography-mass spectrometry
- Noh, Keumhan;
- Kim, Seo Young;
- Kam, Yoo Lim;
- Choo, Hea-Young Park;
- Lee, Hwa Jeong;
- ... Kang, Wonku
WEB OF SCIENCE
7SCOPUS
7초록
A novel T-type calcium channel blocker, 4-amino-1-{4-[(4-chloro-phenyl)-Phenyl-methyl]-piperazin-1-yl}-butan-1-one (HYP-10) has been synthesized, and the compound has shown promise as both a nociceptive and inflammatory pain reliever as well as an analgesic in a rat neuropathic pain model. A quantification method was developed for the determination of HYP-10 in rat plasma. After simple protein precipitation with methanol, HYP-10 and the internal standard, methaqualone were chromatographed on a reversed-phase column and detected by liquid chromatography/tandem mass spectrometry with electrospray ionization. The accuracy and precision of the assay were in accordance with FDA regulations for validation of bioanalytical methods. This method was applied to measure the plasma HYP-10 concentration after a single intravenous administration of the compound in rats. (C) 2010 Elsevier B.V. All rights reserved.
키워드
- 제목
- Determination of a novel low-voltage-activated calcium channel blocker (HYP-10) in rat plasma by liquid chromatography-mass spectrometry
- 저자
- Noh, Keumhan; Kim, Seo Young; Kam, Yoo Lim; Choo, Hea-Young Park; Lee, Hwa Jeong; Kang, Wonku
- 발행일
- 2011-02
- 유형
- Article
- 권
- 54
- 호
- 3
- 페이지
- 568 ~ 571
- 언어
- ENG
- 출판사
- ELSEVIER SCIENCE BV
- 발행국가
- 네덜란드
- 분량
- 4 페이지
- ISSN
- E 1873-264X
P 0731-7085