Diagnostic Performance of the Modified Korean Thyroid Imaging Reporting and Data System for Thyroid Malignancy: A Multicenter Validation Study

  • Chung Sae Rom; 
  • Ahn Hye Shin; 
  • Choi Young Jun; 
  • Lee Ji Ye; 
  • Yoo Roh-Eul; 
  • 외 5명
Citations

WEB OF SCIENCE

25
Citations

SCOPUS

26

초록

Objective: To evaluate the diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System (K-TIRADS), and compare it with the 2016 version of K-TIRADS using the Thyroid Imaging Network of Korea. Materials and Methods: Between June and September 2015, 5708 thyroid nodules (≥ 1.0 cm) from 5081 consecutive patients who had undergone thyroid ultrasonography at 26 institutions were retrospectively evaluated. We used a biopsy size threshold of 2 cm for K-TIRADS 3 and 1 cm for K-TIRADS 4 (modified K-TIRADS 1) or 1.5 cm for K-TIRADS 4 (modified K-TIRADS 3). The modified K-TIRADS 2 subcategorized the K-TIRADS 4 into 4A and 4B, and the cutoff sizes for the biopsies were defined as 1 cm for K-TIRADS 4B and 1.5 cm for K-TIRADS 4A. The diagnostic performance and the rate of unnecessary biopsies of the modified K-TIRADS for detecting malignancy were compared with those of the 2016 K-TIRAD, which were stratified by nodule size (with a threshold of 2 cm). Results: A total of 1111 malignant nodules and 4597 benign nodules were included. The sensitivity, specificity, and unnecessary biopsy rate of the benign nodules were 94.9%, 24.4%, and 60.9% for the 2016 K-TIRADS; 91.0%, 39.7%, and 48.6% for the modified K-TIRADS 1; 84.9%, 45.9%, and 43.5% for the modified K-TIRADS 2; and 76.1%, 50.2%, and 40.1% for the modified K-TIRADS 3. For small nodules (1–2 cm), the diagnostic sensitivity of the modified K-TIRADS decreased by 5.2–25.6% and the rate of unnecessary biopsies reduced by 19.2–32.8% compared with those of the 2016 K-TIRADS (p < 0.001). For large nodules (> 2 cm), the modified K-TIRADSs maintained a very high sensitivity for detecting malignancy (98%). Conclusion: The modified K-TIRADSs significantly reduced the rate of unnecessary biopsies for small (1–2 cm) nodules while maintaining a very high sensitivity for malignancy for large (> 2 cm) nodules.

키워드

Thyroid nodule; Thyroid cancer; Diagnostic performance; Ultrasonography; Fine-needle aspiration; FINE-NEEDLE-ASPIRATION; ASSOCIATION GUIDELINES; BETHESDA SYSTEM; TI-RADS; NODULES; CANCER; SOCIETY; MANAGEMENT; ULTRASOUND; PAPILLARY
제목
Diagnostic Performance of the Modified Korean Thyroid Imaging Reporting and Data System for Thyroid Malignancy: A Multicenter Validation Study
저자
Chung Sae Rom; Ahn Hye Shin; Choi Young Jun; Lee Ji Ye; Yoo Roh-Eul; Lee Yoo Jin; Kim Jee Young; Sung Jin Yong; Kim Ji-hoon; Baek Jung Hwan
DOI
10.3348/kjr.2021.0230
발행일
2021-09
유형
Article
저널명
Korean Journal of Radiology
권
22
호
9
페이지
1579 ~ 1586

파일 다운로드

Thumbnail