관로내 하수흐름의 전단응력 향상을 위한 저수조의 활용에 관한 수리적 고찰

Hydraulic consideration to improve the tractive force of sewage in sewer pipes using a storage tank
  • 박규홍
  • 유순유
  • 이태훈

초록

If sewage flows for an extended time at low velocities, solids may be deposited in the sewer. Sufficient velocity or tractive force should be developed regularly to flush out any solids that may have been deposited during low flow periods. This study aims to evaluate the periods (T) during which sewage flow greater than the minimum tractive force maintains on a spot in sewer pipe system with lower tractive force or lower velocity than expected in the design step, when a storage tank installed in a place upsteam pours water into the sewer. The effect to T of design factors of storage tank and sewer pipes was evaluated assuming the uniform flow in sewers. When the area of orifice in the storage tank is 0.062 ㎡(or 0.28 m diameter), the maximum T of 31sec was maintained using the usually used preset range of values of several design factors. As the horizontal cross section of storage tank and water depth of storage tank and roughness in sewers increase, T linearly increases. Also, T linearly decreases as the diameter of a sewer pipe increases. Although T gradually decreases as the sewer pipe slope decreases to around 0.005, T decreases sharply when the slope is less than 0.003.

키워드

하수관로전단응력저수조침전물악취SewersTractive forceStorage tankSedimentsOdor
제목
관로내 하수흐름의 전단응력 향상을 위한 저수조의 활용에 관한 수리적 고찰
제목 (타언어)
Hydraulic consideration to improve the tractive force of sewage in sewer pipes using a storage tank
저자
박규홍유순유이태훈
DOI
10.11001/jksww.2019.33.2.121
발행일
2019-04
저널명
상하수도학회지
33
2
페이지
121 ~ 129