상세 보기
Determination of the quantity of tolperisone hydrochloride in tablets by high performance liquid chromatography
- Quoc Ky Truong;
- Xuan Lan Mai;
- 김대현;
- 김전경;
- 강종성;
- ... 나동희;
- 외 3명
초록
In attempt to contribute in official monographs of Korean Pharmacopoeia, an HPLC method was developed and fully validated for the determination of tolperisone hydrochloride in tablets which have never been published in other forgein Pharmacopoeia. Analysis was carried out in an ODS column (250 × 4.6 mm I.D., 5 μm) with common solvents include acetonitrile and ammonium hydrophosphate buffer as mobile phase. The assay was validated according to International Conference on Harmonization (ICH) guidelines. The method has good linearity in the range of 5 – 200 μg/mL tolperisone. Intra-day precision varied between 0.04 and 0.10 %. Relative standard deviations of inter-day precision ranged between 0.43 and 1.24 % for peak area. The percentage recovery of the tolperisone ranged between 99.8 and 101.2 % in material. Recoveries in tablets were ranged between 98.7 and 100.8 %, thus confirmed the suitability of method for estimation of tolperisone hydrochloride in tablet dosage form.
키워드
- 제목
- Determination of the quantity of tolperisone hydrochloride in tablets by high performance liquid chromatography
- 저자
- Quoc Ky Truong; Xuan Lan Mai; 김대현; 김전경; 강종성; 우미희; 나동희; 전인구; 김경호
- 발행일
- 2017-02
- 저널명
- 분석과학
- 권
- 30
- 호
- 1
- 페이지
- 32 ~ 38
- 언어
- ENG
- 출판사
- 한국분석과학회
- 발행국가
- 대한민국
- 분량
- 7 페이지
- ISSN
- E 2288-8985
P 1225-0163