Feature-based non-rigid volume registration of serial coronary CT angiography

Citations

SCOPUS

2

초록

Coronary CT angiography (CTA) with multi-slice helical scanners is becoming the integral part of major diagnostic pathways for coronary artery disease. In addition, coronary CTA has demonstrated substantial potential in quantitative coronary plaque characterization. If serial comparisons of plaque progression or regression are to be made, accurate 3D volume registration of these volumes would be particularly useful. In this work, we propose a coronary CTA volume registration of the paired coronary CTA scans using feature-based non-rigid volume registration. We achieve this with a combined registration strategy, which uses the global rigid registration as an initialization, followed by local registration using non-rigid volume registration with a volume preserving constraint. We exploit the extracted coronary trees to help localize and emphasize the region of interest as unnecessary regions hinder registration process, which results in wrong registration result. The extracted binary masks of each coronary tree may not be the same due to initial segmentation errors, which could lead to subsequent bias in the registration process. Therefore we utilize a blur mask which is generated by convolving the Gaussian function with the binary coronary tree mask to include the neighboring vessel region into account. A volume preserving constraint is imposed so that the total volume of the binary mask before and after co-registration remains constant. To validate the proposed method, we perform experiments with data from 3 patients with available serial CT scans (6 scans in total) and measure the distance of anatomical landmarks between the registered serial scans of the same patient.

키워드

Coronary CT angiography (CTA); Image registration; Nonlinear registration; Volume-preserving constraint; 3D volume registration; Anatomical landmarks; Before and after; Binary masks; Coregistration; Coronary artery disease; Coronary CT angiography (CTA); Coronary tree; CT angiography; CT scan; Feature-based; Gaussian functions; Initial segmentation; Integral part; Local registration; Non-rigid; Nonlinear registration; Plaque progression; Region of interest; Registration process; Rigid registration; Volume preserving constraints; Volume registration; Anemometers; Angiography; Diseases; Image registration; Image segmentation; Imaging systems; Medical imaging; Three dimensional
제목
Feature-based non-rigid volume registration of serial coronary CT angiography
저자
Woo, J.; Hong, B.-W.; Dey, D.; Cheng, V.; Ramesh, A.; Sundaramoorthi, G.; Kuo, C.-C.J.; Berman, D.S.; Germano, G.; Slomka, P.J.
DOI
10.1117/12.814146
발행일
2009-03
유형
Conference Paper
저널명
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
권
7259