수동저항부가 형성된 띠형 섬유보강재의 인발저항 특성

Pullout Resistance of Geosynthetic Strip with Rounded Band Anchor

초록

This paper describes the results of pullout tests in the laboratory, which are conducted to assess the pullout performance of recently developed geosynthetic strip reinforcement with rounded band anchor. The geosynthetic strip can be used as reinforcements in reinforced soil wall with concrete block facing. The pullout resistance of the geosynthetic strip with rounded band anchor is mobilized by the combination of the interface friction between soil-reinforcement surface and the passive soil resistance caused by the rounded band anchor. Therefore, both the friction resistance and the passive resistance have to be considered in design. From the pullout test results, when the rounded band anchor are formed in the end part of the geosynthetic strip, pullout strength increases about from 10% to 65%. The passive resistance can be evaluated based on the pullout test results.

키워드

Pullout test; Geosynthetic strip reinforcement; Reinforced soil wall; Pullout resistance; Passive resistance
제목
수동저항부가 형성된 띠형 섬유보강재의 인발저항 특성
제목 (타언어)
Pullout Resistance of Geosynthetic Strip with Rounded Band Anchor
저자
이광우; 조삼덕; 한중근; 홍기권
발행일
2011
저널명
한국지반신소재학회 논문집
권
10
호
3
페이지
43 ~ 51