Comparison of 4 CBCT-IGRT Geometric QA Phantoms within a Single Institutional Workflow

  • Park, Hyojun; 
  • Ryu, Hyejo; 
  • Choi, Jin Hwa; 
  • Park, So-Yeon; 
  • Huh, Yoonsuk; 
  • 외 4명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Objectives: To compare 4 commercial cone-beam CT (CBCT) geometric quality assurance phantoms within a common workflow, focusing on positioning/repositioning accuracy and agreement between the laser-defined setup reference and the CBCT imaging isocenter. Methods: MIMI, QUASAR Penta-Guide, ISOCube, and MZ CUBE were evaluated monthly for 5 months on a Versa HD system with XVI CBCT and a HexaPOD couch. Two observers independently completed each measurement. Three-dimensional post-correction translational residuals (Delta dpos/rep) and laser-defined setup reference-CBCT imaging isocenter distances (Delta diso) were calculated. Phantom comparisons used observer-averaged values from the 5 monthly sessions. Rotational correction and CBCT image quality were assessed descriptively with MZ CUBE. Results: Mean Delta dpos/rep values ranged from 0.19 to 0.31 mm, with mean absolute observer differences of 0.05-0.12 mm. No overall difference was found among the 4 phantoms (P = .547). Mean Delta diso values ranged from 0.68 to 0.87 mm, and all measurements were below 2 mm. An overall difference was observed for Delta diso (P = .019), although no pairwise comparisons were performed. With MZ CUBE, mean post-correction translational and rotational residuals were 0.24 mm and 0.37 degrees, respectively, and image-quality measures showed no consistent temporal trend. Conclusions: The 4 phantoms showed similarly small post-correction translational residuals. In our setting, MZ CUBE additionally supported rotational and image-quality checks. Advances in knowledge: Direct comparison within a common workflow showed similar translational performance, while the scope of additional testing depended on the phantom configuration and locally available accessories.

키워드

cone-beam computed tomography; CBCT; image-guided radiotherapy; IGRT; geometric quality assurance; geometric QA; QA phantom; positioning/repositioning accuracy
제목
Comparison of 4 CBCT-IGRT Geometric QA Phantoms within a Single Institutional Workflow
저자
Park, Hyojun; Ryu, Hyejo; Choi, Jin Hwa; Park, So-Yeon; Huh, Yoonsuk; Kang, Seonghee; Choi, Chang Heon; Kim, Jung-In; Chun, Minsoo
DOI
10.1093/bjr/tqag197
발행일
2026
유형
Article; Early Access
저널명
British Journal of Radiology
권
99
호
1187
페이지
2261 ~ 2265