Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging

  • Choi, Ji Young; 
  • Yun, Jihye; 
  • Heo, Subin; 
  • Kim, Dong Wook; 
  • Choi, Sang Hyun; 
  • ... Kim, Kyuwon; 
  • 외 3명
Citations

WEB OF SCIENCE

9
Citations

SCOPUS

10

초록

Objective Cine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from cine MRI and evaluate its performance in a population with varying degrees of small bowel motility.Materials and Methods A total of 174 participants (28.5 +/- 7.6 years; 135 males) underwent a 22-second-long cine MRI sequence (2-dimensional balanced turbo-field echo; 0.5 seconds per image) approximately 5 minutes after being intravenously administered 10 mg of scopolamine-N-butyl bromide to deliberately create diverse degrees of small bowel motility. In a manually segmented area of the small bowel, motility was automatically quantified using a nonrigid registration and calculated as a quantitative motility score. The mean value (MV) of motility grades visually assessed by two radiologists was used as a reference standard. The quantitative motility score's correlation (Spearman's rho) with the reference standard and performance (area under the receiver operating characteristics curve [AUROC], sensitivity, and specificity) for diagnosing adynamic small bowel (MV of 1) were evaluated.Results For the MV of the quantitative motility scores at grades 1, 1.5, 2, 2.5, and 3, the mean +/- standard deviation values were 0.019 +/- 0.003, 0.027 +/- 0.010, 0.033 +/- 0.008, 0.032 +/- 0.009, and 0.043 +/- 0.013, respectively. There was a significant positive correlation between the quantitative motility score and the MV (rho = 0.531, P < 0.001). The AUROC value for diagnosing a MV of 1 (i.e., adynamic small bowel) was 0.953 (95% confidence interval, 0.923-0.984). Moreover, the optimal cutoff for the quantitative motility score was 0.024, with a sensitivity of 100% (15/15) and specificity of 89.9% (143/159).Conclusion The quantitative motility score calculated from a cine MRI enables diagnosis of an adynamic small bowel, and potentially discerns various degrees of bowel motility.

키워드

Cine imaging; Magnetic resonance imaging; Gastrointestinal motility; Small intestine; Bowel; CHRONIC INTESTINAL PSEUDOOBSTRUCTION; MR ENTEROGRAPHY; DISEASE; PERISTALSIS; INFLAMMATION; DYSMOTILITY
제목
Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging
저자
Choi, Ji Young; Yun, Jihye; Heo, Subin; Kim, Dong Wook; Choi, Sang Hyun; Yoon, Jiyoung; Kim, Kyuwon; Jung, Kee Wook; Myung, Seung-Jae
DOI
10.3348/kjr.2023.0144
발행일
2023-11
유형
Article
저널명
Korean Journal of Radiology
권
24
호
11
페이지
1093 ~ 1101

파일 다운로드

Thumbnail