Background: To investigate the reliability of FDT and 24-2 and 30-2 Humphrey perimetry in children. Methods: We retrospectively reviewed the records corresponding to 274 eyes of children aged 6-12 years, who underwent FDT and 30-2 and 24-2 Humphrey visual field testing fromJanuary 2011 throughMarch 2013. Each test group was divided into two subgroups: a normal visual acuity subgroup (> 0.8 Snellen, group 1) and a low visual acuity subgroup (<= 0.8 Snellen, group 2). Reliability indexes such as fixation losses, test duration, and the number and rate of false-positive errors were analyzed. Results: In both subgroups, test duration was shortest for 24-2 perimetry (group 1: p < 0.0001; group 2: p < 0.0001). FDT was associated with lower rates of fixation loss, false positive errors, and false negative errors than 30-2 perimetry. However, the fixation loss rate of FDT was only significantly lower under the subgroup analysis. The normal visual acuity subgroup had a higher MDscore on FDT vs. 30-2 perimetry (P = 0.028). However, the PSD was similar for all tests. Conclusion: This reliability study showed that FDT perimetry is superior to 30-2 SITA perimetry. There was no significant difference in the reliability indexes for FDT and 24-2 SITA perimetry; thus, when considering test duration and reliability, 24-2 SITA perimetry appears to be the optimal choice in pediatric patients.

키워드

Frequency doubling technology (FDT); reliability indexes; Swedish Interactive Thresholding Algorithm (SITA); visual field test; STANDARD AUTOMATED PERIMETRY; TECHNOLOGY PERIMETRY; GLAUCOMA; MATRIX; AGE
제목
Comparison of Three Visual Field Tests in Children: Frequency Doubling Test, 24-2 and 30-2 SITA Perimetry
저자
Han, Sangyoun; Baek, Seung-Hee; Kim, Ungsoo Samuel
DOI
10.3109/08820538.2016.1157611
발행일
2017-07
유형
Article
저널명
Seminars in Ophthalmology
권
32
호
5
페이지
647 ~ 650