초록

Background and Objectives: There are no data comparing clinical outcomes of complex percutaneous coronary intervention (PCI) between biodegradable polymer-biolimus-eluting stents (BP-BES) and durable polymer-everolimus-eluting stents (DP-EES). We sought to evaluate the safety and efficacy of BP-BES compared with DP-EES in patients undergoing complex PCI. Methods: Patients enrolled in the SMART-DESK registry were stratified into 2 categories based on the complexity of PCI. Complex PCI was defined as having at least one of the following features: unprotected left main lesion, >= 2 lesions treated, total stent length >40 mm, minimal stent diameter <= 2.5 mm, or bifurcation as target lesion. The primary outcome was target lesion failure (TLF), defined as a composite of cardiac death, target vessel-related myocardial infarction (TV-MI), or target lesion revascularization (TLR) at 2 years of follow-up. Results: Of1,999 patients, 1,145 (57.3%) underwent complex PCI: 521 patients were treated with BP-BES and 624 with DP-EES. In propensity-score matching analysis (481 pairs), the risks of TLF (3.8% vs. 5.2%, adjusted hazard ratio [HR], 0.578; 95% confidence interval [CI], 0.246-1.359; p=0.209), cardiac death (2.5% vs. 2.5%, adjusted HR, 0.787; 95% CI, 0.244-2.539; p=0.689), TV-MI (0.5% vs. 0.4%, adjusted HR, 1.128; 95% CI, 0.157-8.093; p=0.905), and TLR (1.1% vs. 2.9%, adjusted HR, 0.390; 95% CI, 0.139-1.095; p=0.074) did not differ between 2 stent groups after complex PCI. Conclusions: Clinical outcomes of BP-BES were comparable to those of DP-EES at 2 years after complex PCI. Our data suggest that use of BP-BES is acceptable, even for complex PCI.

키워드

Coronary artery disease; Percutaneous coronary intervention; Drug-eluting stents; CLINICAL-OUTCOMES; GENERATION; DISEASE; TRIAL; IMPLANTATION
제목
Safety and Efficacy of Biodegradable Polymer-biolimus-eluting Stents (BP-BES) Compared with Durable Polymer-everolimus-eluting Stents (DP-EES) in Patients Undergoing Complex Percutaneous Coronary Intervention
저자
Song, Pil Sang; Park, Kyu Tae; Kim, Min Jeong; Jeon, Ki-Hyun; Park, Jin-Sik; Choi, Rak Kyeong; Song, Young Bin; Choi, Seung-Hyuk; Choi, Jin-Ho; Lee, Sang Hoon; Gwon, Hyeon-Cheol; Jeong, Jin-Ok; Im, Eul Soon; Kim, Sang Wook; Chun, Woo Jung; Oh, Ju Hyeon; Hahn, Joo-Yong
DOI
10.4070/kcj.2018.0097
발행일
2019-01
유형
Article
저널명
Korean Circulation Journal
권
49
호
1
페이지
69 ~ 80