Effectiveness and Safety of Biodegradable Polymer-Coated Everolimus-Eluting Stent in Multivessel Coronary Artery Disease in Routine Clinical Practice: A Korean Multicenter, Prospective, and Observational Study
  • Park, Soohyung
  • Kim, Woohyeun
  • Rha, Seung-Woon
  • Choi, Byoung Geol
  • Hahn, Joo-Yong
  • ... Jeong, Young-Hoon
  • 외 25명
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Background Multivessel coronary artery disease (CAD) poses a significant challenge in interventional cardiology due to its complexity and association with adverse clinical outcomes. Real-world data on the clinical performance of drug-eluting stents in Korean patients with multivessel disease (MVD) are limited. This study aimed to evaluate the efficacy and safety of the biodegradable polymer-coated everolimus-eluting stents (SYNERGY™, Boston Scientific Corporation, Natick, MA, USA) in treating patients with MVD in real-world clinical setting. Methods This multicenter, prospective, observational registry involved 22 hospitals in the Republic of Korea. Eligible patients presented with ≥ 70% stenosis in at least two vessels and were amenable for receiving percutaneous coronary intervention (PCI). The primary endpoint was target lesion failure ([TLF], the composite of cardiac death; target vessel myocardial infarction [MI]; and target lesion revascularization [TLR]) at 1 year. Results Between August 2016 and September 2018, 542 patients were enrolled. The mean age of the patients was 66.2 ± 10.4 years, and most of them were male (73.7%). Diabetes mellitus (DM) was present in 40.8% of patients, while 68.2% had acute coronary syndrome (ACS). The 1-year TLF was in 2.1%, with incidences of cardiac death 0.9%, MI 0.3%, TLR 0.9%, and stent thrombosis 0.3%. Subgroup analysis revealed no significant differences in the primary endpoint between patients with or without ACS, and DM. In-stent restenosis (hazard ratio [HR], 11.20; 95% confidence interval [CI], 2.20–56.91) and total stent length (HR, 1.02; 95% CI, 1.01–1.03) were identified as independent predictors of TLF. Conclusion The 1-year TLF rate observed in our cohort (2.1%) was comparable to or lower than rates previously reported in studies evaluating drug-eluting stents in patients undergoing multivessel PCI. These results suggest that the biodegradable polymer-coated everolimus-eluting stents provide favorable clinical outcomes for this patient population in real-world clinical practice.

키워드

Coronary Artery DiseaseDrug-Eluting StentMultivessel Disease, Percutaneous Coronary Intervention5-YEAR FOLLOW-UP3-VESSEL DISEASELEFT MAINDURABLE POLYMERBYPASS-SURGERYINTERVENTIONDRUGREVASCULARIZATIONMETAANALYSIS
제목
Effectiveness and Safety of Biodegradable Polymer-Coated Everolimus-Eluting Stent in Multivessel Coronary Artery Disease in Routine Clinical Practice: A Korean Multicenter, Prospective, and Observational Study
저자
Park, SoohyungKim, WoohyeunRha, Seung-WoonChoi, Byoung GeolHahn, Joo-YongPark, Sang-HoLee, Han CheolCho, Jang HyunBong, Jung MinHwang, Byung-HeeSeo, Jae-BinJeong, Young-HoonPark, Hyung-BokJeong, Myung HoChoi, Byoung JooChoi, Kyu-YoungLee, Seung UkCho, Youn-HaengHwang, Sun HoPark, KyungilChoi, Yu JeongHer, Ae-YoungLee, Jae BumHwang, Jin-YongChoi, Joon HyoukSinurat, Markz RmpChoi, Se YeonCha, Jin AhHyun, Su JinChoi, Cheol UngPark, Chang Gyu
DOI
10.3346/jkms.2026.41.e85
발행일
2026-03
유형
Article
저널명
Journal of Korean Medical Science
41
9

파일 다운로드